In cardiac operation, the cannula is inserted in root of aorta through which cold arrest liquid is perfused.

Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd

Details

In cardiac operation, it’s a channel to let the oxygenated blood insert into human body.
Two models: Curved (XF) and Straight (XF-1).
Specification Form

Motel

Specification 

Motel

Specification

Curved(XF)

10F

Straight(XF-1)

10F

12F

12F

14F

14F

16F

16F

18F

18F

20F

20F

22F

22F

24F

24F

26F

26F

Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd

Details

Use to carry on precava and postcava incubation when doing open heart surgery
There are reinforced stainless lines within tubing wall to prevent bending. Transparent and smooth tubing with porous structure of injection side.
Match with Guide wire within the inner lumen of cannula.
Two models: One Stage Venous Cannula and Two Stage Venous Cannula.

Specification of One Stage Venous Cannula (Unit: mm)

 

Fr

ID of Machine Side(Tolerance ±0.25)

Total Length(Tolerance±20)

14

6.4/10

400

16

6.4/10

18

6.4/10

20

6.4/10

22

6.4/10

24

6.4/10

26

9.5

380

28

9.5

30

9.5

32

9.5

34

9.5

36

9.5

Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd

Details

Use to absorb secretion from the respiratory tract.
Form 1 Specification List Unit:mm

Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd

Direction for use
Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd  Tainjin plastics research institute Co Ltd

(1)Choice the suitablespecification of suction catheter(diameter, length etc.).
(2) See the sketch map, take off the cap of tube exit on the aspirator switchconnects the aspirator connector tube. The three-ways connector connects thetracheal catheter and respirator tube. Close the irrigation ports when the tubedoes not irrigation.
(3) Adjust the vacuum conditioner of aspirator when absorb the phlegm, thedegree of vacuum of the tube about 80-120mmHg (-10.7~-15.9kpa).
(4) When the closed suction catheter does not use, push the slide valveto close. When absorb the phlegm push the slide valve to open at first. Andthen the suction catheter will be put into the tracheal catheter gentlysimultaneously observe the scale on the suction catheter for control the depth.
(5) After suction withdraws the catheter gently until the protectivesleeve (transparent plastic film) is straight. (At this time the top of suctioncatheter has withdrew the front connector), closed the slide valve.
(6) Irrigation: At this time the slide valve should be closed, put theirrigation port into the container, take off the control valve.